← All UAE engineering insights

Water & Sewerage Operations · UAE · 4 min water-ops brief

How Can Coastal UAE Sewer Networks Pin Saline Groundwater Inflows and Benchmark H2S Scrubber Dosing?

Coastal sewerage operators narrow saline groundwater intrusion without civil excavation by combining existing station conductivity/tide logs with staged night-by-night portable logger placement across upstream manholes, alongside sensor-led H2S odour-scrubber dosing.

Related programme: Water Sentinel · 2-page PDF brief ↓ · 1-page CSV checklist ↓

1. UAE Sewerage Scale & Saline Intrusion Impact

Dubai is investing AED 80 billion in the 75 km Strategic Sewerage Tunnels and 242 km of link sewers to replace over 100 pumping stations and save ~450 GWh/year (Dubai Municipality, 1 Oct 2025; Nodal has no agreement with Dubai Municipality). In coastal catchments, saline groundwater entering sewer branches elevates conductivity, accelerates H2S corrosion and degrades treated-effluent reuse.

2. Portable Logger Placement & Scrubber Dosing Benchmarks

Across 64 simulated campaigns on a synthetic single-station catchment (16 author + 16 held-back + 32 stress seeds), in 32 unseen campaigns Bayesian night-by-night placement of 20 portable conductivity loggers narrowed hidden salt inflows in ~7 nights on average versus 11–15 nights for an experienced engineer moving the same 20 loggers and 19–22 nights for a fixed station meter (59/64 pinned at least 2 of 3 inflows within 5 nights vs 51/64 within 14 nights for the expert). Limits: with 8 or 4 loggers the model made ~4.6 or ~2.8 more wasted checks than the expert, and its lead over the expert is not statistically clear with a deeper water table, a 3-night wasted-check cost or 3× ragging. On odour scrubbers, simulated caustic use fell 12–13% vs a time-banded pH schedule (98% vs 94–97% hours in limit; at 2× sulphide load Nodal's saving fell to 4.5% with 10% hours over limit), while a tuned operator rule on the same accurate H2S sensor used 1–2% less caustic than Nodal with more hours over limit.

3. 4-Week Read-Only Catchment Diagnostic at AED 0 Upfront

Operators start with a 4-week read-only diagnostic on historical station conductivity, flow, H2S logs, network topology and dewatering permits at AED 0 upfront, with zero SCADA login and zero field hardware in weeks 1–4.

Verify on your own historical records at AED 0 upfront — started in writing with zero exploratory calls.

Request written scope & NDA at AED 0

Questions & regulatory scope

Key regulatory & operational questions

Are sensors installed in the sewer network during the initial 4-week diagnostic?

No. Weeks 1 to 4 rely exclusively on read-only historical SCADA logs, network GIS exports and dewatering permits.