Energy & coolingGas Shield Central LPG riser slow-leak & meter discrepancy audit

Which tower needs a leak inspection first?

Night-time supply and metered consumption can diverge before the cause is visible. Give field teams an evidence trail for the risers that warrant inspection.

Gas Shield — Central LPG riser slow-leak & meter discrepancy audit

For LPG distributors, gas billing companies and building owners

Today in the UAE

24 hours to report

A company authorised to deal in petroleum products in Dubai, LPG included, must notify the Supreme Council of Energy of any incident arising from its activity within 24 hours of its occurrence (Executive Council Resolution No. 85 of 2025, Art. 13). Central LPG tanks serve residential communities and buildings in Dubai (Dubai Media Office, 1 Oct 2025).

Proof to date

Simulated, internal review

75 of 77

In simulation, of the 77 slow riser leaks that grew to 0.5 L/min, 75 were flagged for inspection before they reached it, across 16 scenarios not used for tuning. A tuned night-gap threshold rule flagged 56, or 61 when re-tuned. In 32 further scenarios run in a second internal review: 184 of 185, against 130 to 142. False inspections were 0.8 per building a year against 0.7, a difference that is not statistically significant.

How to start

4-week replay of 90 days of meters · AED 0 upfront

90 days of hourly master, flat and shop meter readings for a group of buildings, riser pressure and temperature, riser volumes from drawings, tank telemetry and delivery records. No connection to valves, detectors or alarms. Gaps in the data are listed. Anything later is on terms agreed after the study.

Limits

  • All figures come from our own simulation of 100 towers and 120 tanks. Not yet tested on a real gas network, and no outside or human reviewer has checked the figures.
  • The 77 and the 185 are the simulated leaks that grew dangerous, by reaching 0.5 L/min, not every simulated leak.
  • The check needs hourly readings of the tank meter, riser pressure and temperature and every flat and shop meter, and riser volumes from as-built drawings. Buildings with no master meter or with monthly readings cannot be checked.
  • The lead depends on how fast leaks grow: 12 to 26 points over the rule as first tuned, 8 to 22 over its re-tuned variant.
  • The 0.7 false inspections belong to the rule as first tuned (0.67 to 0.71 across both sets of scenarios). Its re-tuned variants ran at 0.87 to 0.94, against our 0.81.
  • No gain is claimed on tanker planning: against a planner that reorders by days of cover it made about 2% more stops, and up to 4% in sensitivity tests.
For LPG distributors, gas billing companies & building owners

Inside the operating model.

Pilot design

What the first test must prove.

Start at AED 0

2-page executive brief (PDF) ↓1-page read-only CSV checklist (PDF) ↓

Gas Shield field verification
Illustrative image
The decision
Which discrepancy justifies a visit when crews also have meter faults and known demand changes to investigate?
How we would test it
Compare night-time readings with the tower’s own normal pattern and meter history. Qualified personnel inspect and act under the operator’s existing safety procedures.
Evidence & target
Stage: Simulated, internal review (100 simulated towers, 120 tanks; untested on a real network). Of 77 slow riser leaks that grew to 0.5 L/min across 16 unseen scenarios (out of 416 total leaks), 75 were flagged before 0.5 L/min vs 56 (or 61 re-tuned) for a night-gap threshold rule, and 184 of 185 (of ~826) vs 130–142 in 32 second-review scenarios. False inspections were 0.81 vs 0.70 per building per year (0.67–0.94 re-tuned; difference not statistically significant). Needs hourly master, flat/shop meters, riser pressure/temperature and as-built riser volumes. No gain is claimed on tanker routing (~2% to 4% more stops vs days-of-cover).
A first step (AED 0 upfront)
4-week replay at AED 0 upfront on 90 days of hourly master, flat and shop meter readings, riser pressure and temperature, as-built riser volumes and delivery records, with zero connection to valves or alarms. Later work on terms agreed after the study.

Questions & regulatory scope

Common questions · Gas Shield (Central LPG riser slow-leak & meter discrepancy audit)

Designed to work with: Hourly Master & Unit Gas Meters · Riser Pressure, Temperature & As-Built Volume · Manual Technician Action Only

What inputs are required for Gas Shield's night-time riser leak check?

Hourly readings from the master tank/inlet meter and every flat and shop meter, riser pressure and temperature (for line-pack correction) and riser volumes from as-built drawings; towers without a master meter or with monthly readings only cannot run the night check.

Does Gas Shield connect to or reset gas shut-off valves?

Never. It has zero connection to valves, detectors or alarms; qualified technicians inspect and act manually on site under existing safety procedures.

How did false inspection rates compare in simulation?

False inspections were 0.81 per building per year vs 0.70 for the first-tuned threshold rule (0.67–0.94 across re-tuned variants, a difference that is not statistically significant).